AREA MONITOR SYSTEMS
Model # FML-5A SIX DECADE
Model # FML-5B FOUR DECADE
FEATURES:
- ALL PLUG-IN MODULAR
- ANTI-SATURATION FEATURE
- SINGLE OR MULTI-CHANNEL
- STAND-BY BATTERY POWER (OPTIONAL)
- RECORDER OUTPUT
- RACK MOUNTING OR CASE
- HIGH AND LOW LEVEL ALARMS SOLID STATE NON-CONTACTING
- RUGGED HEAVY DUTY GM PROBE FOR LOCAL OR REMOTE MONITORING (UP TO 500 FT CABLE OPTIONAL)
- ENERGY COMPENSATED GM DETECTOR
|
FML-5A / 5B (top), NEMA-4X detector (middle), Optional submersible detector (bottom)
|
APPLICATION: Area Monitoring in
and around nuclear reactors, hot cells irradiators and other facilities
handling radioactive materials or x-rays.
GENERAL DESCRIPTION: The Radiation Monitor
uses a Log Alarm Ratemeter, Power Supply, Alarm Module and ruggedized
GM Probe. Because of the plug-in modular construction, additional
channels can be added. The built-in anti-saturation circuit prevents
the system readings from falling off full scale during an over range
condition. High level alarm can be set at any point on scale. Activation
produces flashing red light on front panel and piercing intermittent
2000 Hz tone. Relay is also closed (or opened) for activation of remote
alarms. A system failure alarm in the form of an amber panel light
(and relay closure) is actuated if signal reading drops below built-in
artificial background rate. Depressing test button on activator module
activates movable check source in detector (option) when installed
and gives check point on meter for system calibration. Rack mounting
or case mounting supplied with up to six readout modules for every
power supply module.
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
AREA MONITOR SYSTEMS
Model # FML-5A SIX DECADE
Model # FML-5B FOUR DECADE
SPECIFICATIONS:
- Response: Log
- Range: 6 decade dynamic range(FML-5A) 1
mR/hr to 1,000 R/hr * (artificial background supplied by internal
radiation source in probe) or .01 mR/hr to 10 R/hr * - optional.
4 decade dynamic range (FML-5B) 0.1 mR/hr to 1 R/hr * (artificial
background supplied by internal radiation source in probe)
* Other ranges available to 1,000 R/hr
- Front Panel Controls:
Selector Switch CAL-Off-On
Hi Level Alarm Set Knob
Lo Level Alarm Set Knob
Alarm Reset Pushbutton
Operate-Calibrate Pushbutton
Hi Voltage Adjust
Power Off-On
Test Button on Activator Module (option)
- Time Constant: Varies inversely with count
rate
- Readout: Meter 100
° 2.4''
scale. Optional: 240° 4.2'' scale
- Output: Positive 5 ± 1 V pulse
output to Scaler, Printer, Computer, etc.
- Connector: 0-1 mA supplied for remote meter
or recorder
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
AREA MONITOR SYSTEMS
Model # FML-5A SIX DECADE
Model # FML-5B FOUR DECADE
SPECIFICATIONS:
- Alarm Features: Non-contacting - all solid
state percentage of full scale type. Settable from 0 to 100% of full
scale. Locking electronically actuated relay provides via DPDT + 5V
at 300 mA plus contact closure (or opening) (3A rating 250V). Alarm
module when triggered has flashing red light and sonalert beeper.
Alarms activated until reset.
- High Level Alarm: Activated when count rate exceeds
set point. Hi-level red light on count rate meter panel goes on in
addition to Beeper and Flasher.
- Low Level Alarm: A small internal radiation source
provides the probe with a count rate which exceeds the setting on
the low-level alarm. Failure of any part of system, including probe,
electronics or power supply, causes indicator to dip below low level
alarm setting and activates alarm. AC failure is indicated also by
pilot light on voltage module going off. Low level amber light on
count rate meter panel goes on in addition to sonalert Beeper and
Flasher.
- Anti-Saturation: Circuitry is incorporated
to prevent readings from falling below full scale in over range conditions
(tested to 1,000 R/hr).
- Emergency Power (option): Standby batteries
operating under continuous charge automatically take over and provide
approximately 8 hours operation in event of AC power failure.
- Line Operation: 105-125 V (or 200-240 V), 50-60 Hz.
- High Voltage Output: 0 to +2,000 V at
200 µA continuously adjustable
- Detector: Energy compensated halogen quenched
GM detectors, in ruggedized probe with internal radiation source.
Supplied with 8 ft cable. (Up to 500 ft of cable can be supplied as
an option).
Optional movable internal radiation source - activated remotely.
- Energy Dependence: ± 20% from 100 KeV to 1.2 MeV
- Console Dimensions: 10-1/4'' W x 8-3/4''
H x 13-1/2'' D (single channel - wider if more than one channel)
or rack mount
- Weight: Console plus detector 21lbs.
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com