FAST, ULTRA-SENSITIVE PORTAL MONITOR
MODEL # PPM-27G
FEATURES:
- FULL DYNAMIC BACKGROUND SUBTRACT
- OUTSTANDING SENSITIVITY TO FISSION PRODUCTS SPECTRUM
- ADVANCED N OF 8 DESIGN
- 8 CHANNELS OF COUNTING ELECTRONICS
- AUDIO AND VISUAL RADIATION ALARMS
- HIGH BACKGROUND ALARM
- LOSS OF SIGNAL LIGHTS
- FAST FLOW THROUGH OF PEOPLE
- EASY TO READ ALARM PANEL FOR MOUNTING ON WALL OR PORTAL
- WEATHER RESISTANT PORTAL AND FOOT DECK
- CHOICE OF PORTAL FRAMES
|
Figure 1: F-36 (top left), F-25A (top right), Alarm panel (bottom).
|
APPLICATION: The PPM-2/G
examines people from head to toe for radioactive contamination.
If placed within a passageway. a large throughput can be attained
with a minimum amount of supervision.
DESCRIPTION: The PPM-27G
consists of a walk through portal frame and separate table
top, (also rack mountable) electronics. A cabinet to hold electronics
and counting gas bottle is optional. Nine, fourteen, or twenty-four
gas flow radiation detectors (depending upon choice of frame) and
one motion detector, sense contamination on a person as he crosses
the threshold. The radiation detectors are grouped into eight separate
channels. This feature makes it easier to locate and remove contamination,
and increases sensitivity by lowering the background count per channel.
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
FAST, ULTRA-SENSITIVE PORTAL MONITOR
MODEL # PPM-27G
When unoccupied, the PPM-27G
averages background radiation over 20 second interval. A first-in-first-out
shift register updates the background data every 0.2 seconds. When
the portal is occupied the electronics com-pare the background plus
1, 1.4, or 2 times the background s standard deviation, to the personnel
count. This comparison is made every 50, 100, or 200 milliseconds
depending upon the setting of the front panel sample time switch.
The level of confidence ( N of 8 ) can be set for each channel using
the eight position switches on the electronics console. Separate alarms
are provided for each channel.
SPECIFICATIONS:
- SENSITIVITY: FOR LARGER PORTAL FRAMES,
F-36 and F-X3:
40 nCi Cs-137 Beta is detected with 95% confidence in 0.4
sec. (It also meets DOE & NRC specifications. NRC requires detection
of ½ gr. plutonium, 3 mm brass shield, 90% confidence,
false alarm rate less than 0.1%, and detection of 3 gm U-235, 20%
enriched, 3 mm brass shield, 50% confidence, false alarm rate less
than 0.1 %.) FOR LIGHTER PORTAL FRAME, F-25: 80 nCi Cs-137 is detected
with 95% confidence in 0.4 sec.
- GAS FLOW DETECTORS: Model:PPG-41. Optionally,
PPG-41T for enhanced gamma sensitivity.
- Sensitivity: 20% of 4 pi Cs-i 37 betas.
Detectors can detect lower energy betas down to .05 MeV.
- Sensitive area: 400 square centimeters
per detector.
- Operating Voltage: Typically 1900 V with
P-10 gas or 2800 V (optional) with Propane.
- Window Thickness: 5 mg/cm2(other
thicknesses optional).
ELECTRONICS CHASSIS:
- Front Panel Controls:
Sigma Multiplier (each channel): 1, 1.4, 2.
N of 8 Alarm Set (each channel): 1, 2, 3, 4, 5, 6, 7, 8.
Sample Time: 50, 100, 200 milliseconds.
Overflow Alarm (for background): 10, 20, 40, 80.
Reset push button
Alarm Disable
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
FAST, ULTRA-SENSITIVE PORTAL MONITOR
MODEL # PPM-27G
SPECIFICATIONS (Continued):
- Rear Panel Controls:
Power on-off
High Voltage Adjust: 0-2000 V for P-10 or Geiger gas
(0-3000 V for propane optional)
- Front Panel Indicators: Average Background
Display (each channel): Two digits.N of 8 Display (each channel):
one digit. Contamination Alarm LED (each channel): red. No Signal
Alarm LED (each channel): yellow.
- Rear Panel Indicators: Power on/off lamp:
red High Voltage Meter, 0-2000 volts, (0-3000V optional)
- Rear Panel Outputs: Remote Alarm Output
Terminals (each channel plus common bell and lamp) Switched AC outlet
- Common Alarms]
- Indicating Contamination: 2000Hz alarm and flashing red beacon.
- Power Requirements: 110 V, 60 Hz, 1 A
(220 V and 50 Hz optional)
- Dimensions: 19"W x 20"D
x 11"H
- Weight: 45 lbs.
- Shipping Weight: 65 lbs.
- ALARM PANEL: Wall mountable, silhouette
with lights indicating location of contamination, plus sonalert and
flashing red light.
- GAS FLOW SYSTEM: Flow meter and micro
metering valve are included. Gas tank and pressure regulators are
normally supplied by user. Timer and solenoid operated valve is available
as an option to further minimize gas usage.
PORTAL FRAME AND FOOT DECK:
Frame Option: |
F-25A |
F-36 |
F-X3 |
Description: |
Lighter Model |
Larger with door |
Walk straight through |
Number of Detectors: |
9 |
14 |
24 |
Inside Dimensions: |
14``W x 79``H |
24``W doorway |
24W`` x 79``H |
|
|
21``W clearance x 79.25``H |
|
Outside Dimensions: |
88``H x 30``W x 28``D |
89.25``H x 43.5``W x 57.25``D |
88``H x 30``W x 30``D |
Flush Mount Height: |
83`` |
87`` |
83`` |
Weight: |
155 lbs. |
400 lbs. |
350 lbs. |
Shipping Weight: |
240 lbs. |
500 lbs. |
450 lbs. |
TA TECHNICAL ASSOCIATES