To On-Line Catalog Similar Products


AIR MONITOR ALPHA, BETA-GAMMA PARTICULATES,
CHEMICALS, AND GAS

Model # SAAM-2HVM

FEATURES:
  • MOVING AIR FILTER
  • AIRBORNE ALPHA AND BETA-GAMMA PARTICULATES
  • RUGGED, 100% DUTY CYCLE
  • SETTABLE ALARM
  • HIGH THROUGHPUT
  • OPERATES FOR LONG PERIODS UNATTENDED
  • PRINTED RECORD
  • NETWORK READY ELECTRONICS
  • 3'' LEAD SHIELD (LIGHTER UNIT AVAILABLE)
  • 3 CHANNEL AIR MONITOR
  • COUNTS SEPARATELY AND SIMULTANEOUSLY
DESCRIPTION: The SAAM-2HVM series are three channel air monitors for simultaneous measuring of gross Alpha, Beta-Gamma particulates and gaseous radioactivity and airborne chemicals and vapors including Iodine. Like all of the SAAM series, these are continuous duty, high capacity, rugged skid or caster-mounted systems. Electronics are microprocessor with color LCD display. Also preamps etc. are plug-in modules allowing change or addition of function as needed and allowing rapid repair by substitution of modules in the field. The modular system is covered by T/A's unique exchange warranty, in addition to the full one year warranty covering all T/A products.
 
SAAM-2HVM Image

Figure 1: SAAM-2HVM
 
  Filter Paper View

Figure 2: Filter Paper
 

Shields are void free lead encased in welded steel and with stainless steel liners for a long, useful life and easy decontamination. Filters are easily changed via quick disconnect, O-ring sealed filter holder. Shield can be opened for filter change or cleaning with minimum effort. All shield connections and openings are sealed against air leaks. The air moving system is based on a high capacity air pump capable of delivering 5 cfm with options up to 30 cfm free air and including fine regulation in the 3 cfm to 5 cfm operating range. The entire system is mounted in a self-contained rugged cabinet and comes complete with all cabling and connectors in place ready to operate. The standard unit is operated from 115 V single phase, 60 Hz; 220 V optional, 50 or 60 Hz. 


TA  TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net     www.tech-associates.com


AIR MONITOR ALPHA, BETA-GAMMA PARTICULATES,
CHEMICALS, AND GAS

Model # SAAM-2HVM

SPECIFICATIONS:

Channels: 1 2 3
Physical Form: Particulates Airborne Chemicals (Including Iodine) Noble Gases
Activity Detected Alpha, Beta-Gamma Beta-Gamma Beta-Gamma
Detector Type: Thin Window GM Spectroscopy Grade NaI(Tl) Scintillator Thin Window GM (2 each)
                     Size: 2'' diameter 2'' diameter x 1'' thick 2'' diameter
                   Model: T-1190 PGS-3L16 T-1190
Filter Media: Moving Filter Activated Charcoal Cartridge Gas Chamber
                     Size: 75mm x 100meters 2.5'' diameter 1 Liter
       Construction: Standard or Glass Fiber Metal Cased Stainless Steel Lined
Standard Shielding: 3'' (Pb) Lead 3'' (Pb) Lead 3'' (Pb) Lead
Optional Shielding: 1'' (Pb) Lead 1'' (Pb) Lead 1'' (Pb) Lead
Sensitivity: 2 x 10-13 µCi/ml 2 x 10-13 µCi/ml 1 x 10-7 µCi/ml

CHANNEL NAME STATUS REAL TIME AIRBORNE CONCENTRATION µCi/m3 (Note 1) ACCUMULATED DOSE FOR THIS SHIFT µCi-Hrs/m3(Note 1) CONCENTRATION AlARM STATUS ACCUMULATED DOSE ALARM
PARTICULATE -- -- -- --
AIRBORNE CHEMICAL -- -- -- --
NOBLE GAS -- -- -- --
Other alarms: status      

  Low Air Flow ___ Loss of Signal Particulate ___
    Loss of Signal Airborne Chemical ___
    Loss of Signal Noble Gas ___
       
MENU OPTIONS: 1. Modify shift length     2. Change filter  
  3. Configure energies 4. Set alarms  
  5. Start shift 6. Save to floppy  

NOTE 1 - User can easily change engineering units at will.

NOTE 2 - High Range Gas can be adjusted to see > 10µCi/ml.

Clear audio and visual alarms are provided.

TA  TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net     www.tech-associates.com


AIR MONITOR ALPHA, BETA-GAMMA PARTICULATES,
CHEMICALS, AND GAS

Model # SAAM-2HVM

Main Screen
 
MAIN DISPLAY SCREEN

Data Screen


DATA.TXT DISPLAY SCREEN SHOWS DATA SAVED TO FLOPPY
Model shown in photo is 7-channel version
DATA REVIEW MODE: (DATA.TXT)
Model SAAM-2HVM continuous air monitor automatically saves all data and set-up parameters to 3.5'' floppy diskette every hour. This data can be reviewed on the color LCD display.

Text Screen


TEST.EXE DISPLAY SCREEN FOR SETTING ENERGIES


TA  TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net     www.tech-associates.com


AIR MONITOR ALPHA, BETA-GAMMA PARTICULATES,
CHEMICALS, AND GAS

Model # SAAM-2HVM

SPECIFICATIONS (continued):
ELECTRONIC SYSTEM DESCRIPTION - Micro-processor is Pentium-based, including:

CPU with data acquisition Keyboard
High resolution, color Color LCD Monitor
Mouse Audio
Manuals Graphics printer for hard copy - 4 trace graphs

3.5'' floppy disk - For data storage - 30 days per disk. CD writer also included.
1 gigabyte hard drive - Stores programs, plus room to add additional new software functions in the future.
Specialized air monitor software.
Technical Associates standard modular series - all solid state.
2 ea. MGA-520 - Fully adjustable single channel analyzer with independent High Voltage power supply;
1 ea. MVR-5R Power Supply.
1 ea. LNM-5 Strip Chart Recorder or GRP-10 graphics printer.
1 ea. Magnehelic gage.



TA  TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net     www.tech-associates.com


AIR MONITOR ALPHA, BETA-GAMMA PARTICULATES,
CHEMICALS, AND GAS

Model # SAAM-2HVM

 


TA  TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net     www.tech-associates.com


To On-Line Catalog Similar Products