AIR MONITOR ALPHA, BETA-GAMMA
PARTICULATES,
CHEMICALS, AND GAS
Model # SAAM-2HVM
FEATURES:
- MOVING AIR FILTER
- AIRBORNE ALPHA AND BETA-GAMMA PARTICULATES
- RUGGED, 100% DUTY CYCLE
- SETTABLE ALARM
- HIGH THROUGHPUT
- OPERATES FOR LONG PERIODS UNATTENDED
- PRINTED RECORD
- NETWORK READY ELECTRONICS
- 3'' LEAD SHIELD (LIGHTER UNIT AVAILABLE)
- 3 CHANNEL AIR MONITOR
- COUNTS SEPARATELY AND SIMULTANEOUSLY
DESCRIPTION: The SAAM-2HVM
series are three channel air monitors for simultaneous measuring
of gross Alpha, Beta-Gamma particulates and gaseous radioactivity
and airborne chemicals and vapors including Iodine. Like all of the
SAAM series, these are continuous duty, high capacity, rugged skid
or caster-mounted systems. Electronics are microprocessor with color
LCD display. Also preamps etc. are plug-in modules allowing change
or addition of function as needed and allowing rapid repair by substitution
of modules in the field. The modular system is covered by T/A's unique
exchange warranty, in addition to the full one year warranty covering
all T/A products.
|
Figure 1: SAAM-2HVM
Figure 2: Filter Paper
|
Shields are void free lead encased in welded steel and with
stainless steel liners for a long, useful life and easy decontamination.
Filters are easily changed via quick disconnect, O-ring sealed filter
holder. Shield can be opened for filter change or cleaning with minimum
effort. All shield connections and openings are sealed against air
leaks. The air moving system is based on a high capacity air pump
capable of delivering 5 cfm with options up
to 30 cfm free air and including fine regulation in the 3 cfm to 5
cfm operating range. The entire system is mounted in a self-contained
rugged cabinet and comes complete with all cabling and connectors
in place ready to operate. The standard unit is operated from 115
V single phase, 60 Hz; 220 V optional, 50 or 60 Hz.
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
AIR MONITOR ALPHA, BETA-GAMMA
PARTICULATES,
CHEMICALS, AND GAS
Model # SAAM-2HVM
SPECIFICATIONS:
Channels: |
1 |
2 |
3 |
Physical Form: |
Particulates |
Airborne Chemicals (Including Iodine) |
Noble Gases |
Activity Detected |
Alpha, Beta-Gamma |
Beta-Gamma |
Beta-Gamma |
Detector Type: |
Thin Window GM |
Spectroscopy Grade NaI(Tl) Scintillator |
Thin Window GM (2 each) |
Size: |
2'' diameter |
2'' diameter x 1'' thick |
2'' diameter |
Model: |
T-1190 |
PGS-3L16 |
T-1190 |
Filter Media: |
Moving Filter |
Activated Charcoal Cartridge |
Gas Chamber |
Size: |
75mm x 100meters |
2.5'' diameter |
1 Liter |
Construction: |
Standard or Glass Fiber |
Metal Cased |
Stainless Steel Lined |
Standard Shielding: |
3'' (Pb) Lead |
3'' (Pb) Lead |
3'' (Pb) Lead |
Optional Shielding: |
1'' (Pb) Lead |
1'' (Pb) Lead |
1'' (Pb) Lead |
Sensitivity: |
2 x 10-13 µCi/ml |
2 x 10-13 µCi/ml |
1 x 10-7 µCi/ml |
- Display Mode: Model SAAM-2HVM features
micro-processor control and color LCD monitor.
- Operation: When SAAM-2HVM continuous air
monitor is in normal operation, the color LCD monitor displays:
CHANNEL NAME STATUS |
REAL TIME AIRBORNE CONCENTRATION µCi/m3 (Note 1) |
ACCUMULATED DOSE FOR THIS SHIFT µCi-Hrs/m3(Note 1) |
CONCENTRATION AlARM STATUS |
ACCUMULATED DOSE ALARM |
PARTICULATE |
-- |
-- |
-- |
-- |
AIRBORNE CHEMICAL |
-- |
-- |
-- |
-- |
NOBLE GAS |
-- |
-- |
-- |
-- |
Other alarms: |
status |
|
|
|
|
Low Air Flow ___ |
Loss of Signal Particulate |
___ |
|
|
Loss of Signal Airborne Chemical |
___ |
|
|
Loss of Signal Noble Gas |
___ |
|
|
|
|
MENU OPTIONS: |
1. Modify shift length |
2. Change filter |
|
|
3. Configure energies |
4. Set alarms |
|
|
5. Start shift |
6. Save to floppy |
|
NOTE 1 - User can easily change engineering units
at will.
NOTE 2 - High Range Gas can be adjusted to see >
10µCi/ml.
Clear audio and visual alarms are provided.
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
AIR MONITOR ALPHA, BETA-GAMMA
PARTICULATES,
CHEMICALS, AND GAS
Model # SAAM-2HVM
MAIN DISPLAY SCREEN
DATA.TXT DISPLAY SCREEN SHOWS DATA
SAVED TO FLOPPY
Model shown in photo is 7-channel version
DATA REVIEW MODE: (DATA.TXT)
Model SAAM-2HVM continuous
air monitor automatically saves all data and set-up parameters to
3.5'' floppy diskette every hour. This data can be reviewed on the
color LCD display.
TEST.EXE DISPLAY SCREEN FOR SETTING ENERGIES
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
AIR MONITOR ALPHA, BETA-GAMMA
PARTICULATES,
CHEMICALS, AND GAS
Model # SAAM-2HVM
SPECIFICATIONS (continued):
ELECTRONIC SYSTEM DESCRIPTION - Micro-processor is Pentium-based, including:
CPU with data acquisition |
Keyboard |
High resolution, color |
Color LCD Monitor |
Mouse |
Audio |
Manuals |
Graphics printer for hard copy - 4 trace graphs |
3.5'' floppy disk - For data storage - 30 days per disk.
CD writer also included.
1 gigabyte hard drive - Stores programs, plus room to add
additional new software functions in the future.
Specialized air monitor software.
Technical Associates standard modular series - all solid state.
2 ea. MGA-520 - Fully adjustable single channel analyzer with
independent High Voltage power supply;
1 ea. MVR-5R Power Supply.
1 ea. LNM-5 Strip Chart Recorder or GRP-10 graphics printer.
1 ea. Magnehelic gage.
- High Voltage Supply: Separately variable
for each detector from 0 to 2000 V. Standard FM-5 modular series.
- Display Monitor: Showing both real time
concentration and accumulated dose for all 3 channels.
- Accuracy: ±10% except for
resolution loss and statistical variation.
- Alarms:
Alarms presettable to any trigger level.
Low Level Alarm: Automatic Reset.
High Level Alarm: High level alarm remains activated until RESET is pushed.
Alarm Indication: Red-High Level, Amber-Low Level.
Audio: 1000 Hz, greater than 80 db. Also see Safety Features below.
- Air Moving System:
Air pump: Extremely
rugged continuous duty Positive displacement low rotating speed pumping
system. Pump is high capacity positive displacement. Pump noise is
reduced by heavy duty muffler.
Pump Drive Motor: 1 HP, 50/60 Hz, capacitor start, induction run.
Flow Gage: Magnehelic 3-10 cfm, 4'' dial.
Flow Control: Automatic flow control settable 0-4 cfm ±0.2 cfm.
Inlet and Outlet: 20 foot 3/4'' hose inlet: 20 foot 1''
hose outlet. May be extended.
Flow Rate: Factory set at 4 cfm, can be reset up to 5 cfm with larger motor and up to 30 cfm with some pluming change.
- Controls:
System: ON-OFF |
Air: ON-OFF |
Printer/Recorder: ON-OFF |
(each channel) High Level Alarm: Set |
(each channel) High Level Alarm: Reset |
(each channel) Low Level Alarm:Set |
(each detector) Voltage: Set |
(each detector) Energy Threshold/Window Set |
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com
AIR MONITOR ALPHA, BETA-GAMMA
PARTICULATES,
CHEMICALS, AND GAS
Model # SAAM-2HVM
- Outputs:
Alarm condition outputs: 1. logic level signal 2. contact closure-or opening.
Ethernet and Optional modem or server.
- Standard Installation: Cabinet of heavy
gauge steel. Skid or caster mounted with 4 five inch ball bearing
casters, two of which are full swiveling.
- Special Safety: Loss of air flow alarm.
Loss of signal alarm. All circuits fused.
- Features: Thermal protection on motor.
(Optional: Positive displacement ROOTS
pump).
- Dimensions: 29'' wide x 31'' long x 41'' high exclusive of casters.
- Weight: 1800 lbs (lighter systems are available).
- Shipping Weight: 2100 lbs (lighter systems are available).
- OPTIONS:
Air monitor available without
air mover or with alternate air movers. Broader range 12 decades.
Different detector types. Three push-button check sources (License
exempt quantities).
Positive Displacement of Roots Blower.
Higher Flow up to 30 cfm.
Lighter system with less shielding.
For example 1'' shielding.
Modem and/or Server.
TA TECHNICAL ASSOCIATES
7051 ETON AVENUE * CANOGA PARK, CA 91303
TELEPHONE (818) 883-7043 * FAX(818) 883-6103
e-mail: tagold@nwc.net www.tech-associates.com