English Chinese Spanish

reservoir



MODEL

PORTABLE

DESCRIPTION

USE LOCATION

NEXGEN-SSS

No / In-Line

Drinking Water Radiation Safety Water Monitor. Continuous Real-Time. Measures at or below EPA/DHS PAG Levels.  Protective Action Guideline (PAG) / Military Drinking Water limits. Computer System Integration

Water & Wastewater Utilities

NEXBETA-ABG

Yes or In-Line

Facility Drinking Water Radiation Safety Monitor.  Continuous Real-Time Radiation In-Line Water Monitor. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline and Military Drinking water limits.  Alpha, Beta, Gamma. 

Schools, Hospitals or Other Facilities with Vulnerable Populations - Water Inlet / Outlet Pipes

NEX-BETA-7 and 9

Yes or In-Line

Beta Only Water Monitor. Continuous Real-Time. Measures at or below EPA/DHS PAG Levels.  Protective Action Guideline (PAG) / Military Drinking Water limits. Computer System Integration

Groundwater, Laboratory or Industry Liquid Waste Stream

UNITECT

No

A Robust, Integrated Chemical, Biological & Radiation Water Monitoring System. Measures at or below EPA/DHS PAG Levels. Protective Action Guideline levels and Military Drinking water limits. Continuous real-time monitoring. Multiple detection goals; all RAD Emitters, 7 chemicals, 12+biologicals. Chemist-In-A-Box. Computer System Integration

Water & Wastewater Utilities

LIQ-X-H3/Radon

Transportable

Water Extraction Monitor. Continuous Real-Time. Self –Measures at or below EPA/DHS PAG Levels.  Protective Action Guideline (PAG) / Military Drinking Water limits. Computer System Integration

Candu Type Reactors, Laboratory or Industry Liquid Waste Stream

PEMO-7

No

Strap On Pipe Radiation Safety Monitor
Quick alarm in case of  waterborne radioactive contamination flowing thru one or more pipes, utilizing a constant check with alarm and data record. Flow rate is not an obstacle.

Water & Wastewater Utilities

PEMO-7LE

Yes

Strap On Pipe Radiation Safety Monitor
Quick alarm in case of  waterborne radioactive contamination flowing thru one or more pipes, utilizing a constant check with alarm and data record. Flow rate is not an obstacle.

Water & Wastewater Utilities

SSS-33-DHC

Yes

Down Hole Tritium in Water Detector. Continuous Real-Time. Measures at or below EPA/DHS PAG Levels.  Protective Action Guideline (PAG) / Military Drinking Water limits.

Wells, Monitoring Bore Holes

 

MODEL

PORTABLE

DESCRIPTION

USE LOCATION

MEDA-5T

Yes

Major Event Radiation Water Detector. Automatic quick alarm in the event that a terrorist dumps radioactive material into a water source or in case of a large industrial, medical or Federal Government release or accident.

Reservoirs, Aqueduct, Surface Water

MEDA-SP

Yes – 2 lbs

Radiation Water Detector. Automatic quick alarm in the event that a terrorist dumps radioactive material into a water source or in case of a industrial, medical or Federal Government release or accident.

Anywhere water needs a quick check.

SSS-22P

Yes

Liquid Scintillation Liquid Counting System. Measures all Alpha & Beta emitters including Carbon-14, Tritium, SR-90, CS-137. Liquid scintillation is the most sensitive technique for on-the-spot tritium measurement.

Anywhere water needs a quick check.

TRIMARAN H2O

In-Line

Automated Flow Through Tritium Monitor. Lowest level process monitor available. Monitoring changes in tritium concentration in primary and secondary coolant, entering or leaving the Recombiner, make-up pond or spent fuel pool, etc.

Nuclear Power, Groundwater, Surface water such as storm drain runoff, rivers, etc.

RADIUM-MCA

Yes

Radium in Water Monitor. System gives on site measurements, detects Radium, Sensitivity 3 Pico curie per Liter Total Radium. Identifies specific Radium nuclides.

Drinking water check for Radium

SSS-33M8R

Yes

Radon Water Monitor. Real Time Continuous. Detects and alerts to rise in radon levels in drinking water.

Hydrofracking Waste, Laboratory or Industry Liquid Waste Stream

RAD-CLEAN SYSTEM-600

No

Radium Removal from Drinking Water. Installation provided anywhere within the USA. Ion exchange system.

Small Water Systems

PROTECTIVE ACTION GUIDE  (PAG)

2009 Chart of Revisions to the Protective Action Guides Manual for Radiological Incidents.
Table 4-1. Derived Response Levels (DRLs) Associated with a Committed Effective Dose (CED) of 0.5 rem Resulting from 1 Year of Ingestion.

PAG-EMMISSIONS

Chart of Major Radiation Emissions gleaned from  Revisions to the Protective Action Guides Manual of listed Nuclides.


Technical Associates
7051 Eton Avenue Canoga Park, CA 91303
Phone: (818) 883-7043    
Fax: (818) 883-6103

EMAIL: info@tech-associates.com